New ANSI/BIFMA X5.7-2007 Standard
Vertical Files - Tests
As you may know, BIFMA has been working on updating the vertical file standard for some time. The proposed new standard for vertical files is currently waiting for ANSI approval. This new version harmonizes the standard with the related standard ANSI/BIFMA X5.9-2004 for Storage Units. We trust this information will be of interest to you. Should you have any questions, please do not hesitate to contact us. Regards,Michel Comtois M.Sc.
President, Micom Laboratories Inc.
| ANSI/BIFMA X 5.3-2007 section # | ANSI/BIFMA X5.3-1997 section # | Major difference(s) |
|---|---|---|
|
1 Scope |
1 Scope |
Added an ISO 17025 requirements exception. |
|
2 Definition |
2 Definition |
Added reference to PD-1 and removed definitions that would have been redundant with it. |
|
3 General |
3 General |
Tolerance for test weights was increased from 2% to 5%. |
|
4 Stability Test |
4 Stability Test |
Editorial changes only |
|
5 Unit Strength Test |
12 Strength Test |
Totally reworked. Adapted from X5.9-2004. |
|
6 Racking resistance test |
11 Racking Resistance Test |
Removed the measurement of the pull force prior to the racking. |
|
7 Drop test |
Nonet |
New test. Harmonized with X5.9-2004. |
|
8 Extendible Element Cycle Test |
8 Extendible Element Cycle Test |
Added Interlock and Stability requirements to the test. No provision for side pulls. Cycle rate changed from 10±2 to 12±4 cycles per minute. Added a resetting interval (no less than 500 cycles). |
|
9 Interlock Test |
14 Interlock Test |
Added a section where the test is performed with the drawers loaded (as per X5.9-2004) |
|
10 Rebound Test |
5 Rebound Test |
Removed the note specifying not to disable a latching mechanism. |
|
11 Out Stop Test |
6 Out Stop Test |
Cycle rate changed from 10±2 to 14±6 cycles per minute. Added a resetting interval (no less than 500 cycles). |
|
12.1 Force Test for Locks |
7 Lock Test |
Editorial changes only |
|
12.2 Locking Mechanism Cycle Test |
None |
New test. Identical to the X5.9-2004 version of this test. Cycling the lock open and close at a rate of 14±6 cycles per minute. |
|
13 Latch Test - Static |
9 Latch Test, Static |
Editorial changes only. |
|
14 Compressor Test |
10 Compressor Test |
Editorial changes only. |
|
15 Pull Force Test |
153Pull Force Test |
Changed from measuring the pull force in two phases (0 to 6 in. and 6 in to end) to one phase (0 to end). Harmonized with all other BIFMA standards. |